Skill # 2-1 | NFPA JPR# & Edition: 2014/2017 | Task: Clean the interior and wash and wax the exterior of a fire department apparatus |
Skill # 2-2 | NFPA JPR# & Edition: 2014/2017 4.2.1,4.2.2 | Task: Perform a routine walk-around maintenance inspection |
Skill # 2-3 | NFPA JPR# & Edition: 2014/2017 4.2.1,4.2.2, 4.3.7 | Task: Perform an in-cab operational inspection |
Skill # 2-4 | NFPA JPR# & Edition: 2014/2017 4.2.1 | Task: Test apparatus road and parking brakes |
Skill # 2-5 | NFPA JPR# & Edition: 2014/2017 4.2.1, 4.2.2 | Task: Perform engine compartment inspection and routine preventive maintenance |
Skill # 2-6 | NFPA JPR# & Edition: 2014/2017 4.2.1 | Task: Charge an apparatus battery. |
Skill # 2-7 | NFPA JPR# & Edition: 1002 2014/2017 4.2.1, 4.2.2, 5.1.1, 5.1.2 | Task: Perform daily inspections for apparatus equipped with a fire pump. |
Skill # 2-8 | NFPA JPR# & Edition: NFPA 1002, 2014 — 4.2.1, 4.2.2, 5.1.1; NFPA 1002, 2017 — 4.2.1, 4.2.2, 5.1.2 | Task: Perform weekly inspections for apparatus equipped with a fire pump. |
Skill # 2-9 | NFPA JPR# & Edition: NFPA 1002, 2014 — 4.2.2, 5.1.1; NFPA 1002, 2017 — 4.2.2, 5.1.2] | Task: Perform a hard intake hose service test. |
Skill # 3-1 | NFPA JPR# & Edition: NFPA 1002, 2014 and 2017 — 4.3.1 | Task: Start, idle, and shut down a fire service apparatus |
Skill # 3-2 | NFPA JPR# & Edition: NFPA 1002, 2014 and 2017 — 4.3.1, 4.3.6, 6.2.1, 7.2.2, 7.2.3 | Task: Drive a fire service apparatus |
Skill # 3-3 | NFPA JPR# & Edition: NFPA 1002, 2014 and 2017 — 4.3.2, 4.3.3, 4.3.4, 4.3.5, 6.2.1, 7.2.1, 7.2.3 | Task: Back apparatus using mirrors |
Skill # 3-4 | NFPA JPR# & Edition: NFPA 1002, 2014 and 2017 — 4.3.2, 4.3.3, 4.3.4, 4.3.5, 4.3.6, 6.2.1, 7.2.1, 7.2.3 | Task: Perform various driving exercises |
Skill # 3-5 | NFPA JPR# & Edition: NFPA 1002, 2014 and 2017 — 4.3.1, 7.2.2 | Task: Perform various road tests in a fire service apparatus |
Skill # 15-1 | NFPA JPR# & Edition: NFPA 1002, 2014 — 4.2.2, 5.1.1; NFPA 1002, 2017 — 4.2.2, 5.1.2 | Task: Perform an engine speed test |
Skill # 15-2 | NFPA JPR# & Edition: NFPA 1002, 2014 — 4.2.2, 5.1.1; NFPA 1002, 2017 — 4.2.2, 5.1.2 | Task: Perform a vacuum test |
Skill # 15-3 | NFPA JPR# & Edition: NFPA 1002, 2014 — 4.2.2, 5.1.1; NFPA 1002, 2017 — 4.2.2, 5.1.2 | Task Prepare the pumper and complete a performance test of a fire pump including the priming system, pumping overload, and pressure control tests |
Skill # 15-4 | NFPA JPR# & Edition: NFPA 1002, 2014 — 4.2.2, 5.1.1; NFPA 1002, 2017 — 4.2.2, 5.1.2 | Task Perform discharge gauge and flowmeter operational tests. |
Skill # 15-5 | NFPA JPR# & Edition: NFPA 1002, 2014 — 4.2.2, 5.1.1; NFPA 1002, 2017 — 4.2.2, 5.1.2 | Task Perform a tank-to-pump flow test |